STERILIZER/AUTOCLAVE
21 CFR Part 11, cGMP standard,ASME/CE Certified
Features:
-- steam on at 121 ºC
-- temperature distribution: 0.5-1.0ºC
-- Working pressure: -1/2.5 bar
-- Full automatic control of pre-programmed sterilization cycles.
-- Touch screen display P&ID with indication
-- 3 levels access password interface.
-- Computer and 6 recorder record production data,recorder and printer print out data
cGMP standard ,ASME/CE Certified
HM ST-D series Dry Heat Sterilizer
Usage: dry heat sterilize apparatus and solid material
Suitable: aluminum cover, vial and ampoules, metal, glass vessels and solid material
Range: design temperature: 300 ºC; class A
Model: HM ST-D0.2/0.6/1/1.2/1.8/5.2
Chamber capacity: 600*500*750/ 800*800*1000/ 900*1000*1200/ 1000*1000*1200/1000*1200*1500/1750*1750*1700mm
Chamber volume:0.225/0.64/1/1.2/1.8/5.2 m2,can specially design other sizes according to customer's requirements.
Sterilization time: 300ºC, 15 minutes/batch; 180 ºC, 2 hours/batch
HM AS series Ampoule Inspection Sterilizer
Usage: steam sterilization for filled ampoule, leak-hunting of sealing
Features:
- steam sterilization at 105-127 ºC
- heating, sterilization, exhaust, leak-hunting, washing, drying, cycle time : 60-90 mins
Model: HM AS-(G/H/S) 0.6/0.8/1.0/1.2/1,5/2.0/2.5/5.0
Capacity: 0.6/0.8/1.0/1.2/1,5/2.0/2.5/5.0 m3
\
HM VL-EW Series Vial & Ampoule External Washer
Usage: Wash and clean vial external surface to remove dirty, dust and remains of materials, then dry it. Suitable for vials, ampoules and other bottles.
Capacity: 100, 200, 300, 400pcs/min
HM VS series Pulse Vacuum Steam Sterilizer
Usage: steam sterilization for biology, instruments, tools, dressing, clothes with pulse vacuum.
Features:
- vacuum program, instruments program, liquid program, B-D testing program.
- sterilization temperature:121-134ºC.
- pulse vacuum, heating, sterilization, cooling, exhaust, cycle time: 30-60 mins/cycle
Model: HM VS-(G/S) 0.24/0.36/0.6/0.8/1.0/1.2/1.5/2.0/2.5/3.0/3.5/4.0/5.0
Capacity: 0.24/0.36/0.6/0.8/1.0/1.2/1.5/2.0/2.5/3.0/3.5/4.0/5.0 m3
HM IS-V series Steam-Air Mixture Sterilizer
Usage: steam-air mixture sterilization for I.V. solution non-PVC or -PVC soft bag
Working principle: heating, sterilizing, air ventilation cooling, re-heat, re-cool, exhaust.
Cycle time:150-170 mins/cycle
Configure: chamber SUS 304(option:SUS316L), Germany pneumatic angle valve, pneumatic system, vortex fan, SIEMENS PLC + computer and touch screen, two doors pneumatic sliding doors sealing and interlock.
Model: Φ2.0m, HM IS-V 13.2/16.9/20.7/24.5/28.3/32.0
Φ2.5m, HM IS-VB 30.3/36.1/41.8/47.6/53.4/59.3
Capaciry: for 500ml, 2160/2880/36000/4320/ 5040/5760, 4500/ 5400/ 6300/7200/8100/9000 pcs/cycle.
HM IS-W series Hot Shower Sterilizer
Usage: hot shower sterilization for I.V. solution glass bottle, PE bottles, PP bottles, non-PVC or PVC soft bag.
Working principle: filling water, heating, sterilization, cooling, drain, exhaust air
Cycle time: 75-90 mins /cycle
Configure: chamber SUS304(option:SUS316L), Germany pneumatic angle valve, STERLING hot cycle pump, pneumatic system, Sweden SWEP plate type heat exchanger, SIEMENS PLC+ computer and touch screen, two doors pneumatic sliding doors sealing and interlock.
Model: Φ2.0m,single track: HM IS-W 13.2/16.9/20.7/24.5/28.3/32.0
Φ2.5m, double track: HM IS-W 30.3/36.1/41.8/47.6/53.4/59.3
Capaciry: for 500ml
Glass bottle:3120/4160/5200/6240/7280/8320,7920/9504/11088/12672/14256/15840 pcs/cycle
Plastic bottle:3780/5040/6300/7560/8820/10080, 8800/ 10560/ 12320/ 14080/15840/17600 pcs/cycle
Soft bag :2160/2880/3600/4320/5040/5700, 3780/ 4536/ 5292/ 6048/6804/7560 pcs/cycle